NSN
6632-01-699-7005
Analyzer,Blood Glucose
FSC 6632 — MEDICAL LABORATORY ANALYSIS INSTRUMENTSFSG 66 — INSTRUMENTS AND LABORATORY EQUIPMENT
2 parts / 2 mfrs
Part Numbers for NSN 6632-01-699-70052 records
Manufacturers (2)
Abbott Point of Care Inc.
CAGE 00WB2Abbott Diagnostics Division
CAGE ZU109Identification Data
DEMIL
A
HMIC
N
PMIC
A
ESD/EMI
A
Item Characteristics
| MRC | Requirement | Reply |
|---|---|---|
| ABRN | HEIGHT | 234.8 MILLIMETERS |
| ACDC | CURRENT TYPE | AC |
| ACZB | FREQUENCY RATING | 47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM |
| APYE | DETECTOR TYPE | SILICON SOLID STATE |
| AQXY | TEST TYPE FOR WHICH DESIGNED | BLOOD GASES, CHEMISTRIES AND ELECTROLYTES, CARDIAC MARKERS, COAGULATION, HEMATOLOGY, ENDOCRINOLOGY. |
| CBBL | FEATURES PROVIDED | DIGITAL DISPLAY SCREEN AND RS232 PORT |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | WIRELESS PORTABLE BLOOD ANALYZER |
| CYFV | METHOD OF ANALYSIS | POTENTIOMETRIC/ION SELECTIVE ELECTRODE |
| CYHM | TEST SAMPLE/SPECIMEN TYPE | BLOOD GASES, CHEMISTRIES AND ELECTROLYTES, CARDIAC MARKERS, COAGULATION, HEMATOLOGY, ENDOCRINOLOGY. |
| DPTH | DEPTH | 72.4 MILLIMETERS |
| ELEC | VOLTAGE IN VOLTS | 100.0 AND 240.0 |
| FEAT | SPECIAL FEATURES | PERFORM PATIENT-SIDE TESTS AND UPLOAD RESULTS TO THE ELECTRONIC MEDICAL RECORD (EMR) AND LAB INFORMATION SYSTEM (LIS) TO ENABLE RAPID TREATMENT DECISIONS, OPTIMIZING PATIENT CARE. PART NUMBER IS FOR OUTSIDE US ONLY. 4-STEP TESTING PROCESS WITH MOST RESULTS IN APPROXIMATELY 2 MINUTES. COMPATIBLE WITH 802.11B/802.11G WIRELESS NETWORKS AND DOES NOT REQUIRE COMMUNICATION VIA BLUETOOTH. WEIGHT: WITH RECHARGEABLE BATTERY 650 GRAMS (22.9 OZ.), WITH DISPOSABLE BATTERY 635 GRAMS (22.4 OZ.). POWER: TWO 9-VOLT LITHIUM BATTERIES, OR RECHARGEABLE BATTERY. CALIBRATION: FACTORY-ELECTRONIC, MECHANICAL, THERMAL, PRESSURE. DISPLAY: DOT MATRIX SUPERTWIST LIQUID CRYSTAL. COMMUNICATION LINK: INFRARED LIGHT-EMITTING DIODE (LED). OPERATING TEMPERATURE: 16-30 C (61-86 F) FOR CARTRIDGE TESTING. TRANSPORT TEMPERATURE: -10-46 C (14-115 F). |
| WDTH | WIDTH | 76.8 MILLIMETERS |
Related NSNs in FSC 6632
6632-01-180-0468— Retainer Kit,Electrode,Blood Gas6632-01-583-6718— Analyzer,Clinical Chemistry6632-00-143-6763— Analyzer,Blood Gas6632-01-732-8146— Analyzer,Clinical Chemistry6632-01-100-35166632-01-601-6834— Analyzer,Blood Gas6632-01-612-3095— Analyzer,Clinical Chemistry6632-01-695-7665— Analyzer,Clinical Chemistry6632-01-692-5935— Timer,Blood and Plasma Coagulati6632-01-683-2741— Analyzer,Clinical Chemistry
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
NSN6632-01-699-7005
NIIN016997005
FSC6632
DEMILA
PARTS2
MFRS2
About NSN 6632-01-699-7005
NSN 6632-01-699-7005 is a National Stock Number assigned to Analyzer,Blood Glucose. This NSN part number belongs to Federal Supply Class 6632 (MEDICAL LABORATORY ANALYSIS INSTRUMENTS) under Federal Supply Group 66 (INSTRUMENTS AND LABORATORY EQUIPMENT). There are 2 part numbers associated with this NSN from 2 manufacturers.
To find the part number for NSN 6632-01-699-7005, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.