6120-01-678-3690
Transformer,Power
Unit Price
$1.00
per EA
2 parts / 1 mfrs
| Part Number | CAGE | Manufacturer | RNCC | RNVC |
|---|---|---|---|---|
| M27/322-05 | 81349 | Military Specifications Promulgated By Military Departments/Agencies Under Authority of Defense Standardization Manual 4120 3-M | 2 | 2 |
| MIL-PRF-27/322 | 81349 | Military Specifications Promulgated By Military Departments/Agencies Under Authority of Defense Standardization Manual 4120 3-M | 4 | 1 |
Military Specifications Promulgated By Military Departments/Agencies Under Authority of Defense Standardization Manual 4120 3-M
CAGE 81349| Effective Date | Unit Price | UI | SLC |
|---|---|---|---|
| 01-OCT-2025 | $1.00 | EA | 0 |
| 01-OCT-2025 | $1.00 | EA | 0 |
DEMIL
A
HMIC
N
PMIC
A
ESD/EMI
A
| MRC | Requirement | Reply |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | 4.659 INCHES MINIMUM AND 4.721 INCHES MAXIMUM |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.484 INCHES MINIMUM AND 3.516 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.734 INCHES MINIMUM AND 2.766 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKW | OVERALL HEIGHT | 6.439 INCHES MINIMUM AND 6.501 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 3.849 INCHES MINIMUM AND 3.911 INCHES MAXIMUM |
| ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZF | MAXIMUM TRANSFORMER POWER RATING | 300.0 VOLT-AMPERE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| AEHZ | MAXIMUM OPERATING TEMP | 130.0 CELSIUS |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | THREADED HOLE(S) SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 12.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 115.0 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | TRANSFORMER, POWER |
| THSD | THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| TTQY | TERMINAL TYPE AND QUANTITY | 5 TURRET |
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
About NSN 6120-01-678-3690
NSN 6120-01-678-3690 is a National Stock Number assigned to Transformer,Power. This NSN part number belongs to Federal Supply Class 6120 (TRANSFORMERS: DISTRIBUTION AND POWER STATION) under Federal Supply Group 61 (ELECTRIC WIRE, AND POWER AND DISTRIBUTION EQUIPMENT). There are 2 part numbers associated with this NSN from 1 manufacturer.
The current government unit price for NSN 6120-01-678-3690 is $1.00. Price history shows 2 recorded price changes.
To find the part number for NSN 6120-01-678-3690, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.