Transformer,Power
Unit Price
$64.60
per EA
1 parts / 1 mfrs
| Part Number | CAGE | Manufacturer | RNCC | RNVC |
|---|---|---|---|---|
| TF58-005-01 | 08748 | Eldec Aerospace Corp | 3 | 2 |
Eldec Aerospace Corp
CAGE 08748| Effective Date | Unit Price | UI | SLC |
|---|---|---|---|
| 01-OCT-2025 | $64.60 | EA | 0 |
| 01-OCT-2025 | $64.60 | EA | 0 |
DEMIL
A
HMIC
P
PMIC
A
ESD/EMI
| MRC | Requirement | Reply |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | 1.770 INCHES MAXIMUM |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.450 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.450 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABMK | OVERALL WIDTH | 1.770 INCHES MAXIMUM |
| ACZB | FREQUENCY RATING | 80.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZF | MAXIMUM TRANSFORMER POWER RATING | 150.0 KILOVOLT-AMPERE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | PRIMARY AND SECONDARY SHIELDED AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| ADAU | BODY HEIGHT | 2.300 INCHES MAXIMUM |
| AEHZ | MAXIMUM OPERATING TEMP | 155.0 CELSIUS |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | THREADED HOLE(S) SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT |
| CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 20.0 AMPERES AC NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 1.3 AMPERES AC NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 15.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| CRBZ | WINDING OPERATING CURRENT | 100.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT FOURTH SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 800.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 20.00 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 44.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 20.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 12.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 44.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| TEST | TEST DATA DOCUMENT | 08748-TF58-005 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| THSD | THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 QUICK DISCONNECT, MALE AND 11 WIRE LEAD |
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
About NSN 5950-01-347-5451
NSN 5950-01-347-5451 is a National Stock Number assigned to Transformer,Power. This NSN part number belongs to Federal Supply Class 5950 (COILS AND TRANSFORMERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 1 part number associated with this NSN from 1 manufacturer.
The current government unit price for NSN 5950-01-347-5451 is $64.60. Price history shows 2 recorded price changes.
To find the part number for NSN 5950-01-347-5451, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.