NSN
5950-01-009-0971
Transformer,Power
FSC 5950 — COILS AND TRANSFORMERSFSG 59 — ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS
1 parts / 1 mfrs
Part Numbers for NSN 5950-01-009-09711 records
| Part Number | CAGE | Manufacturer | RNCC | RNVC |
|---|---|---|---|---|
| 593R139A01 | 97942 | Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp | 3 | 2 |
Manufacturers (1)
Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp
CAGE 97942Identification Data
DEMIL
A
HMIC
P
PMIC
U
ESD/EMI
Item Characteristics
| MRC | Requirement | Reply |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 3.020 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 3.020 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 2.750 INCHES NOMINAL |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | THREADED HOLE(S) SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT |
| CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
| CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 330.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 4.1 AMPERES AC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 5.7 AMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 3.3 AMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| CRMJ | WINDING POWER RATING | 75.5 VOLTS-AMPERES SINGLE COMPONENT FOURTH SECONDARY |
| CRMJ | WINDING POWER RATING | 82.5 VOLTS-AMPERES SINGLE COMPONENT FIRST SECONDARY |
| CRMJ | WINDING POWER RATING | 6.1 VOLTS-AMPERES SINGLE COMPONENT THIRD SECONDARY |
| CRMJ | WINDING POWER RATING | 93.1 VOLTS-AMPERES SINGLE COMPONENT SECOND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 16.30 AC VOLTS MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 18.50 AC VOLTS MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 25.30 AC VOLTS MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 18.50 AC VOLTS MAXIMUM SINGLE COMPONENT FOURTH SECONDARY |
| THSD | THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| TTQY | TERMINAL TYPE AND QUANTITY | 15 TURRET |
Related NSNs in FSC 5950
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
NSN5950-01-009-0971
NIIN010090971
FSC5950
DEMILA
PARTS1
MFRS1
About NSN 5950-01-009-0971
NSN 5950-01-009-0971 is a National Stock Number assigned to Transformer,Power. This NSN part number belongs to Federal Supply Class 5950 (COILS AND TRANSFORMERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 1 part number associated with this NSN from 1 manufacturer.
To find the part number for NSN 5950-01-009-0971, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.