NSN
5950-00-984-5196
Transformer,Power
FSC 5950 — COILS AND TRANSFORMERSFSG 59 — ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS
2 parts / 2 mfrs
Part Numbers for NSN 5950-00-984-51962 records
| Part Number | CAGE | Manufacturer | RNCC | RNVC |
|---|---|---|---|---|
| 376A738H01 | 79500 | Westinghouse Electric Corp | 5 | 2 |
| 376A738H01 | 97942 | Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp | 3 | 2 |
Manufacturers (2)
Westinghouse Electric Corp
CAGE 79500Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp
CAGE 97942Identification Data
DEMIL
A
HMIC
P
PMIC
U
ESD/EMI
Item Characteristics
| MRC | Requirement | Reply |
|---|---|---|
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.120 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABTD | MOUNTING SLOT WIDTH | 0.190 INCHES NOMINAL SINGLE GROUP |
| ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 2.880 INCHES NOMINAL |
| ADAT | BODY WIDTH | 3.090 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 2.810 INCHES NOMINAL |
| AKNA | INCLOSURE TYPE | OPEN |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | FLANGE AND SLOT SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT |
| CRBZ | WINDING OPERATING CURRENT | 350.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 350.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 350.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 900.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 114.00 AC VOLTS NOMINAL AND 120.00 AC VOLTS NOMINAL AND 126.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| TTQY | TERMINAL TYPE AND QUANTITY | 12 TAB, SOLDER LUG |
Related NSNs in FSC 5950
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
NSN5950-00-984-5196
NIIN009845196
FSC5950
DEMILA
PARTS2
MFRS2
Manufacturers
About NSN 5950-00-984-5196
NSN 5950-00-984-5196 is a National Stock Number assigned to Transformer,Power. This NSN part number belongs to Federal Supply Class 5950 (COILS AND TRANSFORMERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 2 part numbers associated with this NSN from 2 manufacturers.
To find the part number for NSN 5950-00-984-5196, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.