5950-00-945-0652
Transformer,Power
Unit Price
$310.04
per EA
4 parts / 4 mfrs
| Part Number | CAGE | Manufacturer | RNCC | RNVC |
|---|---|---|---|---|
| 73C828-003 | 04660 | Ail Systems Inc Sub of Eaton Corp | 3 | 9 |
| 73C828-003 | 72964 | Robert M. Hadley Company, Inc. | 5 | 2 |
| 172061-000 | 81413 | Bae Systems Information and Electronic Systems Integration Inc. Dba Bae Systems | 5 | 2 |
| 73C828-003 | 90095 | Inrcore, Llc Div Inrcore | 5 | 2 |
Ail Systems Inc Sub of Eaton Corp
CAGE 04660Robert M. Hadley Company, Inc.
CAGE 72964Bae Systems Information and Electronic Systems Integration Inc. Dba Bae Systems
CAGE 81413Inrcore, Llc Div Inrcore
CAGE 90095| Effective Date | Unit Price | UI | SLC |
|---|---|---|---|
| 01-OCT-2025 | $310.04 | EA | 0 |
DEMIL
A
HMIC
P
PMIC
A
ESD/EMI
| MRC | Requirement | Reply |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.552 INCHES MINIMUM AND 1.572 INCHES MAXIMUM SINGLE MOUNTING FACILITY FOURTH CENTER GROUP |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.109 INCHES MINIMUM AND 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY SECOND CENTER GROUP |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.109 INCHES MINIMUM AND 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY THIRD CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.672 INCHES MINIMUM AND 1.704 INCHES MAXIMUM SINGLE MOUNTING FACILITY SECOND CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY FOURTH CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.672 INCHES MINIMUM AND 1.704 INCHES MAXIMUM SINGLE MOUNTING FACILITY THIRD CENTER GROUP |
| ABKW | OVERALL HEIGHT | 1.859 INCHES MINIMUM AND 1.891 INCHES MAXIMUM |
| ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 3.859 INCHES MINIMUM AND 3.891 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 2.172 INCHES MINIMUM AND 2.204 INCHES MAXIMUM |
| AEHZ | MAXIMUM OPERATING TEMP | 170.0 CELSIUS |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.109 INCHES MINIMUM AND 1.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY FIRST CENTER GROUP |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 THIRD GROUP |
| AKPV | MOUNTING FACILITY QUANTITY | 4 FOURTH GROUP |
| AKPV | MOUNTING FACILITY QUANTITY | 2 FIRST GROUP |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SECOND GROUP |
| AXGY | MOUNTING METHOD | THREADED HOLE(S) ALL GROUPINGS |
| BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY AND 6 SECONDARY SINGLE COMPONENT |
| CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SECOND GROUP |
| CQJX | NOMINAL THREAD SIZE | 0.164 INCHES FOURTH GROUP |
| CQJX | NOMINAL THREAD SIZE | 0.138 INCHES FIRST GROUP |
| CQJX | NOMINAL THREAD SIZE | 0.112 INCHES THIRD GROUP |
| CRBZ | WINDING OPERATING CURRENT | 600.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT FOURTH SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 40.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 40.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 84.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| CRMJ | WINDING POWER RATING | 13.86 VOLTS-AMPERES SINGLE COMPONENT SECOND SECONDARY |
| CRMJ | WINDING POWER RATING | 5.46 VOLTS-AMPERES SINGLE COMPONENT FIRST SECONDARY |
| CRMJ | WINDING POWER RATING | 1.8 VOLTS-AMPERES SINGLE COMPONENT FOURTH SECONDARY |
| CRMJ | WINDING POWER RATING | 1.6 VOLTS-AMPERES SINGLE COMPONENT THIRD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 41.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 40.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 65.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 3.00 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 8.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 346.50 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| FEAT | SPECIAL FEATURES | TWO PRIMARY WINDINGS; SIX SECONDARY WINDINGS |
| TEST | TEST DATA DOCUMENT | 04660-73C828 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| THSD | THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) ALL GROUPINGS |
| TTQY | TERMINAL TYPE AND QUANTITY | 25 TURRET |
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
About NSN 5950-00-945-0652
NSN 5950-00-945-0652 is a National Stock Number assigned to Transformer,Power. This NSN part number belongs to Federal Supply Class 5950 (COILS AND TRANSFORMERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 4 part numbers associated with this NSN from 4 manufacturers.
The current government unit price for NSN 5950-00-945-0652 is $310.04.
To find the part number for NSN 5950-00-945-0652, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.