5950-00-875-6829
Transformer,Power
5 parts / 4 mfrs
Nai Technologies Inc
CAGE 07342L3harris Interstate Electronics Corporation
CAGE 07421North Atlantic Industries, Inc. Dba North Atlantic Industries
CAGE 0VGU1Magnetic Windings Company Inc
CAGE 76095DEMIL
A
HMIC
P
PMIC
U
ESD/EMI
| MRC | Requirement | Reply |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABTD | MOUNTING SLOT WIDTH | 0.188 INCHES NOMINAL SINGLE GROUP |
| ACZB | FREQUENCY RATING | 45.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL AND INTERNAL SHIELD GROUNDED TO TERMINAL SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 2.312 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 2.062 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 3.125 INCHES MAXIMUM |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | FLANGE AND SLOT SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
| CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 100.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL AND 125.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 230.00 AC VOLTS NOMINAL AND 250.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 55.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| TTQY | TERMINAL TYPE AND QUANTITY | 12 WIRE LEAD |
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
About NSN 5950-00-875-6829
NSN 5950-00-875-6829 is a National Stock Number assigned to Transformer,Power. This NSN part number belongs to Federal Supply Class 5950 (COILS AND TRANSFORMERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 5 part numbers associated with this NSN from 4 manufacturers.