5950-00-648-5841
Transformer,Power
4 parts / 4 mfrs
Magnetek Inc Huntington Div
CAGE 04386Magnetek Inc Lighting Products Group
CAGE 0LG51Freed Transformer Co
CAGE 73386Us Army Communications & Electronics Materiel Readiness Command Logistics Engineering Dir
CAGE 80063DEMIL
A
HMIC
P
PMIC
U
ESD/EMI
| MRC | Requirement | Reply |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | 8.000 INCHES MAXIMUM |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 6.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 5.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKW | OVERALL HEIGHT | 9.562 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 7.375 INCHES MAXIMUM |
| ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
| ADAU | BODY HEIGHT | 9.000 INCHES MAXIMUM |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | THREADED STUD(S) SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| CMLP | THREAD QUANTITY PER INCH | 18 SINGLE GROUP |
| CQJX | NOMINAL THREAD SIZE | 0.312 INCHES SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 12.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 5.00 AC VOLTS NOMINAL AND 16.50 AC VOLTS NOMINAL AND 28.00 AC VOLTS NOMINAL AND 39.00 AC VOLTS NOMINAL AND 50.50 AC VOLTS NOMINAL AND 61.00 AC VOLTS NOMINAL AND 73.00 AC VOLTS NOMINAL AND 84.50 AC VOLTS NOMINAL AND 95.50 AC VOLTS NOMINAL AND 107.00 AC VOLTS NOMINAL AND 118.00 AC VOLTS NOMINAL AND 119.50 AC VOLTS NOMINAL AND 120.50 AC VOLTS NOMINAL AND 122.00 AC VOLTS NOMINAL AND 123.00 AC VOLTS NOMINAL AND 124.00 AC VOLTS NOMINAL AND 125.00 AC VOLTS NOMINAL AND 126.00 AC VOLTS NOMINAL AND 127.00 AC VOLTS NOMINAL AND 128.00 AC VOLTS NOMINAL AND 129.50 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
| THSD | THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| TTQY | TERMINAL TYPE AND QUANTITY | 26 TAB, SOLDER LUG |
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
About NSN 5950-00-648-5841
NSN 5950-00-648-5841 is a National Stock Number assigned to Transformer,Power. This NSN part number belongs to Federal Supply Class 5950 (COILS AND TRANSFORMERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 4 part numbers associated with this NSN from 4 manufacturers.
To find the part number for NSN 5950-00-648-5841, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.