5950-00-645-5783
Transformer,Power
Unit Price
$464.69
per EA
3 parts / 3 mfrs
Us Army Communications & Electronics Materiel Readiness Command Logistics Engineering Dir
CAGE 80063Inrcore, Llc Div Inrcore
CAGE 90095Thordarson Inc
CAGE 96256| Effective Date | Unit Price | UI | SLC |
|---|---|---|---|
| 01-OCT-2025 | $464.69 | EA | 0 |
| 01-OCT-2025 | $464.69 | EA | 0 |
DEMIL
A
HMIC
P
PMIC
U
ESD/EMI
| MRC | Requirement | Reply |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 7.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKW | OVERALL HEIGHT | 4.062 INCHES MAXIMUM |
| ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 8.000 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 3.625 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 3.500 INCHES MAXIMUM |
| AEHZ | MAXIMUM OPERATING TEMP | 105.0 CELSIUS |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | THREADED STUD(S) SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT |
| CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 65.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 16.5 AMPERES AC NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 35.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT FOURTH SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| CRMJ | WINDING POWER RATING | 104.0 VOLTS-AMPERES SINGLE COMPONENT FIRST SECONDARY |
| CRMJ | WINDING POWER RATING | 17.4 VOLTS-AMPERES SINGLE COMPONENT SECOND SECONDARY |
| CRMJ | WINDING POWER RATING | 110.0 VOLTS-AMPERES SINGLE COMPONENT THIRD SECONDARY |
| CRMJ | WINDING POWER RATING | 21.0 VOLTS-AMPERES SINGLE COMPONENT FOURTH SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | UNABLE TO DECODE |
| CWJS | WINDING OPERATING VOLTAGE | UNABLE TO DECODE |
| CWJS | WINDING OPERATING VOLTAGE | UNABLE TO DECODE |
| CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 268.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 550.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 600.00 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | UNABLE TO DECODE |
| THSD | THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| TTQY | TERMINAL TYPE AND QUANTITY | 14 TURRET |
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
About NSN 5950-00-645-5783
NSN 5950-00-645-5783 is a National Stock Number assigned to Transformer,Power. This NSN part number belongs to Federal Supply Class 5950 (COILS AND TRANSFORMERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 3 part numbers associated with this NSN from 3 manufacturers.
The current government unit price for NSN 5950-00-645-5783 is $464.69. Price history shows 2 recorded price changes.
To find the part number for NSN 5950-00-645-5783, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.