5950-00-455-5987
Transformer,Power
Unit Price
$258.02
per EA
1 parts / 1 mfrs
Us Army Aviation and Missile Command
CAGE 18876| Effective Date | Unit Price | UI | SLC |
|---|---|---|---|
| 01-OCT-2025 | $258.02 | EA | 0 |
DEMIL
A
HMIC
P
PMIC
U
ESD/EMI
| MRC | Requirement | Reply |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.117 INCHES MINIMUM AND 2.137 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.665 INCHES MINIMUM AND 1.685 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 2.870 INCHES NOMINAL |
| ADAT | BODY WIDTH | 2.370 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 4.000 INCHES NOMINAL |
| AEHZ | MAXIMUM OPERATING TEMP | 130.0 CELSIUS |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | THREADED STUD(S) SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT |
| CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 18.0 AMPERES AC NOMINAL SINGLE COMPONENT ALL SECONDARY |
| CRMJ | WINDING POWER RATING | 70.02 VOLTS-AMPERES SINGLE COMPONENT THIRD SECONDARY |
| CRMJ | WINDING POWER RATING | 28.08 VOLTS-AMPERES SINGLE COMPONENT FIRST SECONDARY |
| CRMJ | WINDING POWER RATING | 42.12 VOLTS-AMPERES SINGLE COMPONENT SECOND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 3.89 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 1.56 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 2.34 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| THSD | THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| TTQY | TERMINAL TYPE AND QUANTITY | 22 TURRET |
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
About NSN 5950-00-455-5987
NSN 5950-00-455-5987 is a National Stock Number assigned to Transformer,Power. This NSN part number belongs to Federal Supply Class 5950 (COILS AND TRANSFORMERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 1 part number associated with this NSN from 1 manufacturer.
The current government unit price for NSN 5950-00-455-5987 is $258.02.
To find the part number for NSN 5950-00-455-5987, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.