5950-00-231-5277
Transformer,Power
5 parts / 5 mfrs
| Part Number | CAGE | Manufacturer | RNCC | RNVC |
|---|---|---|---|---|
| KS13118 | 06KW9 | Lucent Technologies Inc Dba Federal Marketing Group | 5 | 9 |
| KS13118 | 3B4M0 | Lucent Technologies Inc Corporate Headquarters | C | 1 |
| KS13118 | 64959 | American Telephone and Telegraph Co | 3 | 9 |
| KS13118 | 70408 | At and T Corp | 5 | 9 |
| SCC34142 | 80063 | Us Army Communications & Electronics Materiel Readiness Command Logistics Engineering Dir | 3 | 2 |
Lucent Technologies Inc Dba Federal Marketing Group
CAGE 06KW9Lucent Technologies Inc Corporate Headquarters
CAGE 3B4M0American Telephone and Telegraph Co
CAGE 64959At and T Corp
CAGE 70408Us Army Communications & Electronics Materiel Readiness Command Logistics Engineering Dir
CAGE 80063DEMIL
A
HMIC
P
PMIC
U
ESD/EMI
| MRC | Requirement | Reply |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.437 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKW | OVERALL HEIGHT | 6.031 INCHES NOMINAL |
| ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 4.500 INCHES NOMINAL |
| ADAT | BODY WIDTH | 3.375 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 5.250 INCHES NOMINAL |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | THREADED STUD(S) SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY AND 3 SECONDARY SINGLE COMPONENT |
| CMLP | THREAD QUANTITY PER INCH | 28 SINGLE GROUP |
| CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 1.85 AMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 5.10 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 6.40 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 600.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| FEAT | SPECIAL FEATURES | MOISTURE RESISTANCE AND INSULATION PER SPEC MIL-T-27 GRADE 1 CLASS A |
| THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
| TTQY | TERMINAL TYPE AND QUANTITY | 11 STANDOFF INSULATOR |
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
About NSN 5950-00-231-5277
NSN 5950-00-231-5277 is a National Stock Number assigned to Transformer,Power. This NSN part number belongs to Federal Supply Class 5950 (COILS AND TRANSFORMERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 5 part numbers associated with this NSN from 5 manufacturers.
To find the part number for NSN 5950-00-231-5277, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.