Item Characteristics
| MRC | Requirement | Reply |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | 9.250 INCHES NOMINAL |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 6.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKW | OVERALL HEIGHT | 7.625 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 5.625 INCHES NOMINAL |
| ABTB | MOUNTING HOLE DIAMETER | 0.375 INCHES NOMINAL SINGLE GROUP |
| ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZF | MAXIMUM TRANSFORMER POWER RATING | 1.5 KILOVOLT-AMPERE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED, DOUBLE SHELL |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | FLANGE AND UNTHREADED HOLE(S) SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| CRBZ | WINDING OPERATING CURRENT | 6.0 AMPERES AC NOMINAL FIRST COMPONENT FIRST PRIMARY |
| CRBZ | WINDING OPERATING CURRENT | 7.1 AMPERES AC NOMINAL THIRD COMPONENT THIRD PRIMARY |
| CRBZ | WINDING OPERATING CURRENT | 7.1 AMPERES AC NOMINAL SECOND COMPONENT SECOND PRIMARY |
| CRMJ | WINDING POWER RATING | 1500.0 WATTS SINGLE COMPONENT SINGLE SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 210.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| TTQY | TERMINAL TYPE AND QUANTITY | 1 CABLE W/CONNECTOR AND 1 CONNECTOR, RECEPTACLE |
Related NSNs in FSC 5950
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
NSN5950-00-164-9800
NIIN001649800
FSC5950
DEMILA
PARTS1
MFRS1
Manufacturers
About NSN 5950-00-164-9800
NSN 5950-00-164-9800 is a National Stock Number assigned to Transformer,Power. This NSN part number belongs to Federal Supply Class 5950 (COILS AND TRANSFORMERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 1 part number associated with this NSN from 1 manufacturer.
To find the part number for NSN 5950-00-164-9800, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.