5950-00-152-1837
Transformer,Power
3 parts / 2 mfrs
| Part Number | CAGE | Manufacturer | RNCC | RNVC |
|---|---|---|---|---|
| 11295520 | 17773 | Ballistic Missile Defense Systems Command | 3 | 9 |
| MILT27 | 81349 | Military Specifications Promulgated By Military Departments/Agencies Under Authority of Defense Standardization Manual 4120 3-M | 4 | 1 |
| TF4RX02YY | 81349 | Military Specifications Promulgated By Military Departments/Agencies Under Authority of Defense Standardization Manual 4120 3-M | 4 | 1 |
Ballistic Missile Defense Systems Command
CAGE 17773Military Specifications Promulgated By Military Departments/Agencies Under Authority of Defense Standardization Manual 4120 3-M
CAGE 81349DEMIL
A
HMIC
P
PMIC
U
ESD/EMI
| MRC | Requirement | Reply |
|---|---|---|
| ABHP | OVERALL LENGTH | 9.880 INCHES MAXIMUM |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 7.855 INCHES MINIMUM AND 7.905 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 5.555 INCHES MINIMUM AND 5.605 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKW | OVERALL HEIGHT | 6.647 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 8.540 INCHES MAXIMUM |
| ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE AND THREE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-OPEN DELTA |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 9.880 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 8.540 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 5.757 INCHES MAXIMUM |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | THREADED STUD(S) SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
| CMLP | THREAD QUANTITY PER INCH | 16 SINGLE GROUP |
| CQJX | NOMINAL THREAD SIZE | 0.375 INCHES SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 100.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 28.6 AMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 25.50 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 79.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| FEAT | SPECIAL FEATURES | PRIMARY WINDINGS TAPPED TO VARY OUTPUT VOLTAGES BY 5 PCT |
| THSD | THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| TTQY | TERMINAL TYPE AND QUANTITY | 12 SOLDER STUD AND 3 THREADED STUD |
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
About NSN 5950-00-152-1837
NSN 5950-00-152-1837 is a National Stock Number assigned to Transformer,Power. This NSN part number belongs to Federal Supply Class 5950 (COILS AND TRANSFORMERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 3 part numbers associated with this NSN from 2 manufacturers.
To find the part number for NSN 5950-00-152-1837, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.