NSN
5950-00-050-1167
Transformer,Power
FSC 5950 — COILS AND TRANSFORMERSFSG 59 — ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS
2 parts / 2 mfrs
Part Numbers for NSN 5950-00-050-11672 records
| Part Number | CAGE | Manufacturer | RNCC | RNVC |
|---|---|---|---|---|
| 10167736 | 18876 | Us Army Aviation and Missile Command | 5 | 2 |
| 792-406711 | 53110 | Viasys Respiratory Care Inc. Dba Biosys Healthcare | 3 | 2 |
Manufacturers (2)
Us Army Aviation and Missile Command
CAGE 18876Viasys Respiratory Care Inc. Dba Biosys Healthcare
CAGE 53110Identification Data
DEMIL
A
HMIC
P
PMIC
U
ESD/EMI
Item Characteristics
| MRC | Requirement | Reply |
|---|---|---|
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.281 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 2.750 INCHES NOMINAL |
| ADAT | BODY WIDTH | 2.120 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 4.750 INCHES NOMINAL |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | THREADED STUD(S) SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT |
| CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
| CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 800.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 70.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 200.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 200.00 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 117.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| THSD | THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| TTQY | TERMINAL TYPE AND QUANTITY | 12 SOLDER STUD |
Related NSNs in FSC 5950
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
NSN5950-00-050-1167
NIIN000501167
FSC5950
DEMILA
PARTS2
MFRS2
Manufacturers
About NSN 5950-00-050-1167
NSN 5950-00-050-1167 is a National Stock Number assigned to Transformer,Power. This NSN part number belongs to Federal Supply Class 5950 (COILS AND TRANSFORMERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 2 part numbers associated with this NSN from 2 manufacturers.