5945-01-088-8071
Relay,Electromagnetic
5 parts / 3 mfrs
| Part Number | CAGE | Manufacturer | RNCC | RNVC |
|---|---|---|---|---|
| J412DM2-12PL | 11532 | Teledyne Defense Electronics, Llc Dba Teledyne Relays Div Https://Www.Teledyne.Com/What-We-Do/ | 5 | 1 |
| M39016/15-019L | 81349 | Military Specifications Promulgated By Military Departments/Agencies Under Authority of Defense Standardization Manual 4120 3-M | 2 | 2 |
| MIL-PRF-39016/15 | 81349 | Military Specifications Promulgated By Military Departments/Agencies Under Authority of Defense Standardization Manual 4120 3-M | 4 | 1 |
| MIL-R-39016/15 | 81349 | Military Specifications Promulgated By Military Departments/Agencies Under Authority of Defense Standardization Manual 4120 3-M | 5 | 9 |
| 2422 132 05979 | D9645 | Thales Deutschland Gmbh Div Naval | 5 | 2 |
Teledyne Defense Electronics, Llc Dba Teledyne Relays Div Https://Www.Teledyne.Com/What-We-Do/
CAGE 11532Military Specifications Promulgated By Military Departments/Agencies Under Authority of Defense Standardization Manual 4120 3-M
CAGE 81349Thales Deutschland Gmbh Div Naval
CAGE D9645DEMIL
A
HMIC
N
PMIC
U
ESD/EMI
| MRC | Requirement | Reply |
|---|---|---|
| ABHP | OVERALL LENGTH | 0.280 INCHES MAXIMUM |
| ADAV | OVERALL DIAMETER | 0.370 INCHES MAXIMUM |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| AKDX | WINDING QUANTITY | 1 |
| APCN | COIL QUANTITY | 1 |
| APNA | WINDING DC RESISTANCE RATING | 390.0 OHMS NOMINAL SINGLE WINDING |
| APNP | DUTY TYPE | CONTINUOUS |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PRINTED CIRCUIT TERMINAL SINGLE MOUNTING FACILITY |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CRXH | TIME DELAY | 0.002 SECONDS NOMINAL FIXED OPERATE TIME |
| CRXH | TIME DELAY | 0.004 SECONDS NOMINAL FIXED RELEASE TIME |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 200.0 MILLIAMPERES DC INDUCTIVE LOAD |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC RESISTIVE LOAD |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 MILLIAMPERES DC LAMP LOAD |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
| TEST | TEST DATA DOCUMENT | 81349-MILR39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
| ZZZK | SPECIFICATION/STANDARD DATA | 81349-MILR39016/15 PROFESSIONAL/INDUSTRIAL ASSOCIATION SPECIFICATION |
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
About NSN 5945-01-088-8071
NSN 5945-01-088-8071 is a National Stock Number assigned to Relay,Electromagnetic. This NSN part number belongs to Federal Supply Class 5945 (RELAYS AND SOLENOIDS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 5 part numbers associated with this NSN from 3 manufacturers.
To find the part number for NSN 5945-01-088-8071, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.