NSN
5925-01-700-3491
Circuit Breaker
FSC 5925 — CIRCUIT BREAKERSFSG 59 — ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS
4 parts / 3 mfrs
Part Numbers for NSN 5925-01-700-34914 records
| Part Number | CAGE | Manufacturer | RNCC | RNVC |
|---|---|---|---|---|
| IULHK111-1REC4R-65-15.0-AE-01 | 81541 | Sensata Technologies Maryland, Inc | 5 | 2 |
| AM345 REV BV | 82647 | Sensata Technologies, Inc. Div Sensata Attleboro | D | 9 |
| IULHK111-1REC4R-65-15.0-AE-01 | 82647 | Sensata Technologies, Inc. Div Sensata Attleboro | 3 | 2 |
| 92186447 | F6481 | Thales Sa | 5 | 2 |
Manufacturers (3)
Sensata Technologies Maryland, Inc
CAGE 81541Sensata Technologies, Inc. Div Sensata Attleboro
CAGE 82647Thales Sa
CAGE F6481Identification Data
DEMIL
A
HMIC
P
PMIC
A
ESD/EMI
A
Item Characteristics
| MRC | Requirement | Reply |
|---|---|---|
| AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| ABHP | OVERALL LENGTH | 62.86 MILLIMETERS MINIMUM AND 63.62 MILLIMETERS MAXIMUM |
| ABKW | OVERALL HEIGHT | 82.89 MILLIMETERS MINIMUM AND 86.95 MILLIMETERS MAXIMUM |
| ABMK | OVERALL WIDTH | 57.53 MILLIMETERS MAXIMUM |
| ADAQ | BODY LENGTH | 62.86 MILLIMETERS MINIMUM AND 63.62 MILLIMETERS MAXIMUM |
| ADAT | BODY WIDTH | 57.53 MILLIMETERS MAXIMUM |
| ADAU | BODY HEIGHT | 50.02 MILLIMETERS MINIMUM AND 51.54 MILLIMETERS MAXIMUM |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 18.67 MILLIMETERS MINIMUM AND 19.43 MILLIMETERS MAXIMUM |
| AEGJ | SWITCH CONTACT ARRANGEMENT | DOUBLE POLE, SINGLE THROW, NORMALLY OPEN AND DOUBLE POLE, DOUBLE THROW |
| AGAV | END ITEM IDENTIFICATION | RADAR M/BA |
| AJEC | BOSS HEIGHT | 3.18 MILLIMETERS MINIMUM AND 3.94 MILLIMETERS MAXIMUM |
| AKPX | POLE QUANTITY | 3 |
| CBBL | FEATURES PROVIDED | ROHS DIRECTIVE COMPLIANCE AND TRIP INDICATOR |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES AC ALL LOCATIONS |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 277.0 AC AND 480.0 AC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 15.0 AC ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
| CPRK | AUXILIARY TRIP COIL VOLTAGE TYPE AND RATING IN VOLTS | 277.0 AC MINIMUM AND 480.0 AC MAXIMUM ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
| CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP ALL LOCATIONS |
| CQQC | TRIP RELEASE DUTY CYCLE | CONTINUOUS ALL LOCATIONS |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 6.0 MINIMUM AT 150 PCT AND 60.0 MAXIMUM AT 150 PCT ALL LOCATIONS |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | MOISTURE RESISTANT AND SALT SPRAY PROOF |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 CELSIUS NOMINAL ALL LOCATIONS |
| CRTK | SWITCH TERMINAL TYPE | SCREW AND QUICK DISCONNECT, MALE |
| CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 15.0 AC |
| CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 277.0 AC AND 480.0 AC |
| CTJS | UNPACKAGED UNIT WEIGHT | 270.0 GRAMS NOMINAL |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | HYDRAULIC MAGNETIC CIRCUIT PROTECTOR |
| FEAT | SPECIAL FEATURES | ONE HANDLE PER POLE. STUD TERMINALS. THREE POLES. AUXILIARY SWITCH, 0.110 QUICK CONNECT, AUXILIARY CONNECTORS REVERSED. 50/60 HZ LONG DELAY. 15 AMP. METRIC THREAD MOUNTING INSERTS AND TERMINALS. 277/480 VAC (50/60 HZ). BLACK. AMBIENT OPERATION TEMPERATURES BETWEEN -40 C TO +85 C. INSULATION RESISTANCE: NOT LESS THAN 100 MEGOHMS AT 500 VOLTS DC. MOISTURE RESISTANCE: MEET ALL THE REQUIREMENTS OF MIL-PRF-55629 WHEN TESTED IN ACCORDANCE WITH METHOD 106 OF MIL-STD-202. SHOCK: CIRCUIT PROTECTORS SHALL NOT TRIP WHEN TESTED PER MIL-STD-202, METHOD 213, TEST CONDITION I WITH 100 PCT RATED CURRENT APPLIED TO DELAYED UNITS AND 80 PCT RATED CURRENT TO INSTANTANEOUS UNITS. VIBRATION: CIRCUIT PROTECTORS SHALL NOT TRIP WHEN VIBRATED PER MIL-STD-202, METHOD 204, TEST CONDITION A WITH 100 PCT RATED CURRENT APPLIED TO DELAYED UNITS AND 80 PCT RATED CURRENT TO INSTANTANEOUS UNITS. |
| FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
| MATT | MATERIAL | PLASTIC CASE |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 SCREW AND 3 QUICK DISCONNECT, MALE |
Related NSNs in FSC 5925
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
NSN5925-01-700-3491
NIIN017003491
FSC5925
DEMILA
PARTS4
MFRS3
Manufacturers
About NSN 5925-01-700-3491
NSN 5925-01-700-3491 is a National Stock Number assigned to Circuit Breaker. This NSN part number belongs to Federal Supply Class 5925 (CIRCUIT BREAKERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 4 part numbers associated with this NSN from 3 manufacturers.
To find the part number for NSN 5925-01-700-3491, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.