5925-01-600-8047
Circuit Breaker
3 parts / 3 mfrs
| Part Number | CAGE | Manufacturer | RNCC | RNVC |
|---|---|---|---|---|
| 121B30-B2M | 11873 | Mcgraw Edison Co Usd Opns Sub of Cooper Industries | 5 | 9 |
| 121B30-B2M | 1JY78 | Cooper Bussmann, Llc | 3 | 2 |
| CB-30A | Z08X2 | Customair Conditioning Pty Ltd Customair Automotive Air | 5 | 2 |
Mcgraw Edison Co Usd Opns Sub of Cooper Industries
CAGE 11873Cooper Bussmann, Llc
CAGE 1JY78Customair Conditioning Pty Ltd Customair Automotive Air
CAGE Z08X2DEMIL
A
HMIC
P
PMIC
A
ESD/EMI
A
| MRC | Requirement | Reply |
|---|---|---|
| AAQL | BODY STYLE | SINGLE POLE TYPE |
| ABMK | OVERALL WIDTH | 0.790 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 1.240 INCHES NOMINAL |
| ADAT | BODY WIDTH | 0.790 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 0.640 INCHES NOMINAL |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.690 INCHES NOMINAL |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.196 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.560 INCHES NOMINAL |
| AJEC | BOSS HEIGHT | 0.560 INCHES NOMINAL |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.250 INCHES NOMINAL |
| AKPX | POLE QUANTITY | 1 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE(S) |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 30.0 AMPERES DC ALL LOCATIONS |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 14.0 DC AND 28.0 DC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1.5 DC ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| CPRQ | RESET METHOD | AUTOMATIC |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
| CQJX | NOMINAL THREAD SIZE | 0.190 INCHES |
| CQQC | TRIP RELEASE DUTY CYCLE | CONTINUOUS ALL LOCATIONS |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | -40.0 FAHRENHEIT MINIMUM AND 185.0 FAHRENHEIT MAXIMUM ALL LOCATIONS |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | SERIES 12X SHORTSTOP CIRCUIT BREAKER,30AMP DC |
| THSD | THREAD SERIES DESIGNATOR | UNF |
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
About NSN 5925-01-600-8047
NSN 5925-01-600-8047 is a National Stock Number assigned to Circuit Breaker. This NSN part number belongs to Federal Supply Class 5925 (CIRCUIT BREAKERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 3 part numbers associated with this NSN from 3 manufacturers.