5925-01-330-8678
Circuit Breaker
Unit Price
$247.75
per EA
5 parts / 5 mfrs
| Part Number | CAGE | Manufacturer | RNCC | RNVC |
|---|---|---|---|---|
| 841425-1 | 06481 | Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp | 5 | 2 |
| 841425-1 | 13973 | Litton Systems Inc. Div Navigation Systems Division | 3 | 9 |
| CD5-Z14-1 | 1W134 | Eaton Corp Aerospace Commercial Controls Div | 5 | 9 |
| CD5-Z14-1 | 74193 | Eaton Corp Heinemann Products Commercial Controls Div | 5 | 9 |
| CD5-Z30-1 | L3330 | Heinemann Electric Canada Incdivision of Eaton Corp | 5 | 2 |
Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp
CAGE 06481Litton Systems Inc. Div Navigation Systems Division
CAGE 13973Eaton Corp Aerospace Commercial Controls Div
CAGE 1W134Eaton Corp Heinemann Products Commercial Controls Div
CAGE 74193Heinemann Electric Canada Incdivision of Eaton Corp
CAGE L3330| Effective Date | Unit Price | UI | SLC |
|---|---|---|---|
| 01-OCT-2025 | $247.75 | EA | 0 |
| 01-OCT-2025 | $247.75 | EA | 0 |
| 01-OCT-2025 | $247.75 | EA | 0 |
| 01-OCT-2025 | $247.75 | EA | 0 |
| 01-OCT-2025 | $247.75 | EA | 0 |
DEMIL
A
HMIC
P
PMIC
A
ESD/EMI
| MRC | Requirement | Reply |
|---|---|---|
| AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| ABTD | MOUNTING SLOT WIDTH | 0.164 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 4.740 INCHES MINIMUM AND 4.760 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 5.180 INCHES MAXIMUM |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 3.537 INCHES MINIMUM AND 3.557 INCHES MAXIMUM |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.740 INCHES MINIMUM AND 2.760 INCHES MAXIMUM |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AJEC | BOSS HEIGHT | 0.209 INCHES MINIMUM AND 0.229 INCHES MAXIMUM |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 3.475 INCHES MINIMUM AND 3.495 INCHES MAXIMUM |
| AKPX | POLE QUANTITY | 5 |
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 10 THREADED HOLE(S) AND 5 SLOT |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES DC FIFTH LOCATION |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC FIRST LOCATION |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC THIRD LOCATION |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC SECOND LOCATION |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES DC FOURTH LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC THIRD LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 140.0 DC FIFTH LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC FIRST LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 140.0 DC FOURTH LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC SECOND LOCATION |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC SECOND LOCATION |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC FIRST LOCATION |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC THIRD LOCATION |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 DC FOURTH LOCATION |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 DC FIFTH LOCATION |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
| CPRK | AUXILIARY TRIP COIL VOLTAGE TYPE AND RATING IN VOLTS | 25.0 DC NOMINAL FIRST LOCATION |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 5 TOGGLE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
| CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, THREE, FOUR, AND FIVE LINKED |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SECOND LOCATION |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP FIFTH LOCATION |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP FOURTH LOCATION |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES/RELAY TRIP FIRST LOCATION |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP THIRD LOCATION |
| CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
| CQQC | TRIP RELEASE DUTY CYCLE | CONTINUOUS FIRST LOCATION |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 20.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT FIRST LOCATION |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 25.000 MINIMUM AT 200 PCT AND 95.000 MAXIMUM AT 200 PCT FOURTH LOCATION |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 20.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT THIRD LOCATION |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 25.000 MINIMUM AT 200 PCT AND 95.000 MAXIMUM AT 200 PCT FIFTH LOCATION |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 20.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT SECOND LOCATION |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | VIBRATION RESISTANT AND SHOCK RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF |
| FEAT | SPECIAL FEATURES | FULL LENGTH BARRIERS BETWEEN POLES INCLUDED |
| FREQ | FREQUENCY IN HERTZ | 60.0 FIRST LOCATION |
| FREQ | FREQUENCY IN HERTZ | 60.0 SECOND LOCATION |
| FREQ | FREQUENCY IN HERTZ | 60.0 THIRD LOCATION |
| MATT | MATERIAL | PLASTIC CASE |
| THSD | THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | 12 THREADED STUD |
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp
CAGE 06481
Litton Systems Inc. Div Navigation Systems Division
CAGE 13973
Eaton Corp Aerospace Commercial Controls Div
CAGE 1W134
Eaton Corp Heinemann Products Commercial Controls Div
CAGE 74193
Heinemann Electric Canada Incdivision of Eaton Corp
CAGE L3330
About NSN 5925-01-330-8678
NSN 5925-01-330-8678 is a National Stock Number assigned to Circuit Breaker. This NSN part number belongs to Federal Supply Class 5925 (CIRCUIT BREAKERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 5 part numbers associated with this NSN from 5 manufacturers.
The current government unit price for NSN 5925-01-330-8678 is $247.75. Price history shows 5 recorded price changes.
To find the part number for NSN 5925-01-330-8678, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.