NSN

5925-01-302-8952

Circuit Breaker

FSC 5925CIRCUIT BREAKERSFSG 59ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS

2 parts / 2 mfrs

Part Numbers for NSN 5925-01-302-89522 records
Part NumberCAGEManufacturerRNCCRNVC
APL-111-1REC2-59-051-MA81541Sensata Technologies Maryland, Inc32
91567649F6481Thales Sa52
Manufacturers (2)

Sensata Technologies Maryland, Inc

CAGE 81541
View NSNs
Identification Data

DEMIL

A

HMIC

P

PMIC

U

ESD/EMI

Item Characteristics
MRCRequirementReply
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
ADAQBODY LENGTH2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
ADATBODY WIDTH2.265 INCHES MAXIMUM
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.925 INCHES MINIMUM AND 1.955 INCHES MAXIMUM
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
AEGJSWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJECBOSS HEIGHT0.135 INCHES MINIMUM AND 0.165 INCHES MAXIMUM
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE2.491 INCHES MAXIMUM
AKPXPOLE QUANTITY3
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE(S)
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE50.0 MILLIAMPERES DC ALL LOCATIONS
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS65.0 DC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS2000.0 DC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODMAGNETIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICINSTANTANEOUS ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT115.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY3 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED
CPRZAUXILIARY SWITCH FUNCTION AND QUANTITY1 ALARM
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
CQJXNOMINAL THREAD SIZE3.0 MILLIMETERS
CQQRTHREAD PITCH IN MILLIMETERS0.50
CQSMSWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE ONE
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT
CRTKSWITCH TERMINAL TYPEQUICK DISCONNECT, MALE
CSSXSWITCH CURRENT RATING AND TYPE IN AMPS10.0 AC AND 3.0 DC
CSWPSWITCH VOLTAGE RATING AND TYPE IN VOLTS250.0 AC AND 50.0 DC
CTJSUNPACKAGED UNIT WEIGHT11.100 OUNCES NOMINAL
MATTMATERIALPLASTIC CASE
THSDTHREAD SERIES DESIGNATORISO S
TTQYTERMINAL TYPE AND QUANTITY6 THREADED STUD

Need full procurement data, packaging, and standardization info?

View Complete NSN Data on NSN Lookup

Quick Reference

NSN5925-01-302-8952
NIIN013028952
FSC5925
DEMILA
PARTS2
MFRS2

About NSN 5925-01-302-8952

NSN 5925-01-302-8952 is a National Stock Number assigned to Circuit Breaker. This NSN part number belongs to Federal Supply Class 5925 (CIRCUIT BREAKERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 2 part numbers associated with this NSN from 2 manufacturers.

To find the part number for NSN 5925-01-302-8952, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.