5925-01-249-9066
Circuit Breaker
Unit Price
$22.26
per EA
2 parts / 2 mfrs
| Part Number | CAGE | Manufacturer | RNCC | RNVC |
|---|---|---|---|---|
| 260-1048-080 | 13499 | Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems | 3 | 2 |
| 203-1-6911-080 | 81541 | Sensata Technologies Maryland, Inc | 5 | 2 |
Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems
CAGE 13499Sensata Technologies Maryland, Inc
CAGE 81541| Effective Date | Unit Price | UI | SLC |
|---|---|---|---|
| 01-OCT-2025 | $22.26 | EA | 0 |
DEMIL
A
HMIC
P
PMIC
A
ESD/EMI
| MRC | Requirement | Reply |
|---|---|---|
| AAQL | BODY STYLE | SINGLE POLE TYPESINGLE POLE TYPE |
| ADAQ | BODY LENGTH | 2.000 INCHES NOMINAL2.000 INCHES NOMINAL |
| ADAT | BODY WIDTH | 0.920 INCHES NOMINAL0.920 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 1.770 INCHES NOMINAL1.770 INCHES NOMINAL |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGEDMODERATELY RUGGED |
| AJEC | BOSS HEIGHT | 0.521 INCHES NOMINAL0.521 INCHES NOMINAL |
| AKPX | POLE QUANTITY | 11 |
| APNQ | ARC QUENCHING METHOD | AIRAIR |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 CLIP2 CLIP |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 500.0 MILLIAMPERES AC AND 500.0 MILLIAMPERES DC SINGLE LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC AND 32.0 DC SINGLE LOCATION |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC AND 1000.0 DC SINGLE LOCATION |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.500 MINIMUM AT 200 PCT AND 8.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION |
| MATT | MATERIAL | PLASTIC CASE |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG |
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
About NSN 5925-01-249-9066
NSN 5925-01-249-9066 is a National Stock Number assigned to Circuit Breaker. This NSN part number belongs to Federal Supply Class 5925 (CIRCUIT BREAKERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 2 part numbers associated with this NSN from 2 manufacturers.
The current government unit price for NSN 5925-01-249-9066 is $22.26.
To find the part number for NSN 5925-01-249-9066, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.