NSN

5925-01-196-5123

Circuit Breaker

FSC 5925CIRCUIT BREAKERSFSG 59ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS

2 parts / 2 mfrs

Part Numbers for NSN 5925-01-196-51232 records
Part NumberCAGEManufacturerRNCCRNVC
43-20-P10-F31-RS04F5AMP06402Oakland Industries Ltd52
C12123-181755Lockheed Martin Corporation Div Lockheed Martin Aeronautics Company32
Manufacturers (2)

Oakland Industries Ltd

CAGE 06402
View NSNs

Lockheed Martin Corporation Div Lockheed Martin Aeronautics Company

CAGE 81755
View NSNs
Identification Data

DEMIL

A

HMIC

P

PMIC

A

ESD/EMI

Item Characteristics
MRCRequirementReply
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
ABXDBUSHING LENGTH0.040 INCHES NOMINAL
ADAQBODY LENGTH2.130 INCHES NOMINAL
ADATBODY WIDTH1.650 INCHES NOMINAL
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.960 INCHES NOMINAL
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.740 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.950 INCHES NOMINAL
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE1.610 INCHES NOMINAL
AKPXPOLE QUANTITY2
AXHRMOUNTING FACILITY TYPE AND QUANTITY2 CLIP
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE5.0 AMPERES AC AND 5.0 AMPERES DC ALL LOCATIONS
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 AC AND 28.0 DC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS50.0 AC AND 50.0 DC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODTHERMAL ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONBETWEEN POLE ONE AND TWO
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT10.000 MINIMUM AT 200 PCT AND 40.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDCORROSION RESISTANT
CRCFTRIP RELEASE AMBIENT TEMP RATING-35.0 CELSIUS MINIMUM AND 55.0 CELSIUS MAXIMUM ALL LOCATIONS
FREQFREQUENCY IN HERTZ50.0 OR 60.0 ALL LOCATIONS
MATTMATERIALPLASTIC CASE
TTQYTERMINAL TYPE AND QUANTITY4 QUICK DISCONNECT, MALE

Need full procurement data, packaging, and standardization info?

View Complete NSN Data on NSN Lookup

Quick Reference

NSN5925-01-196-5123
NIIN011965123
FSC5925
DEMILA
PARTS2
MFRS2

About NSN 5925-01-196-5123

NSN 5925-01-196-5123 is a National Stock Number assigned to Circuit Breaker. This NSN part number belongs to Federal Supply Class 5925 (CIRCUIT BREAKERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 2 part numbers associated with this NSN from 2 manufacturers.

To find the part number for NSN 5925-01-196-5123, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.