NSN

5925-01-152-6896

Circuit Breaker

FSC 5925CIRCUIT BREAKERSFSG 59ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS

1 parts / 1 mfrs

Part Numbers for NSN 5925-01-152-68961 records
Part NumberCAGEManufacturerRNCCRNVC
ETN-9719-2030086L3harris Maritime Power & Energy Solutions, Inc. Dba Spd Electrical Systems, Inc.39
Manufacturers (1)

L3harris Maritime Power & Energy Solutions, Inc. Dba Spd Electrical Systems, Inc.

CAGE 30086
View NSNs
Identification Data

DEMIL

A

HMIC

P

PMIC

A

ESD/EMI

Item Characteristics
MRCRequirementReply
AAQLBODY STYLEMULTIPOLE-SINGLE ACTUATOR TYPE
ADAQBODY LENGTH4.125 INCHES NOMINAL
ADATBODY WIDTH3.034 INCHES NOMINAL
ADAUBODY HEIGHT3.375 INCHES NOMINAL
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH2.625 INCHES NOMINAL
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.125 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH0.625 INCHES NOMINAL
AEGJSWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.938 INCHES NOMINAL
AJECBOSS HEIGHT0.125 INCHES NOMINAL
AKPXPOLE QUANTITY3
AXHRMOUNTING FACILITY TYPE AND QUANTITY6 CLIP
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE420.0 AMPERES AC ALL LOCATIONS
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS500.0 AC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS75000.0 AC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODTHERMAL-MAGNETIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE TWO
CPRZAUXILIARY SWITCH FUNCTION AND QUANTITY2 ALARM
CQSMSWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE TWO AND INTERNAL AT POLE THREE
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT20.000 MINIMUM AT 600 PCT AND 180.000 MAXIMUM AT 600 PCT ALL LOCATIONS
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT
CRCFTRIP RELEASE AMBIENT TEMP RATING50.0 CELSIUS NOMINAL ALL LOCATIONS
CRTKSWITCH TERMINAL TYPEPIN
CSWPSWITCH VOLTAGE RATING AND TYPE IN VOLTS115.0 AC AND 120.0 DC
FREQFREQUENCY IN HERTZ400.0 ALL LOCATIONS
MATTMATERIALPLASTIC CASE
TTQYTERMINAL TYPE AND QUANTITY6 COMPRESSION

Need full procurement data, packaging, and standardization info?

View Complete NSN Data on NSN Lookup

Quick Reference

NSN5925-01-152-6896
NIIN011526896
FSC5925
DEMILA
PARTS1
MFRS1

About NSN 5925-01-152-6896

NSN 5925-01-152-6896 is a National Stock Number assigned to Circuit Breaker. This NSN part number belongs to Federal Supply Class 5925 (CIRCUIT BREAKERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 1 part number associated with this NSN from 1 manufacturer.

To find the part number for NSN 5925-01-152-6896, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.