NSN

5925-00-646-3111

Circuit Breaker

FSC 5925CIRCUIT BREAKERSFSG 59ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS

2 parts / 2 mfrs

Part Numbers for NSN 5925-00-646-31112 records
Part NumberCAGEManufacturerRNCCRNVC
711530-605869Raytheon Company Div Rmd Strategic32
711530-682577Raytheon Company Dba Raytheon52
Manufacturers (2)

Raytheon Company Div Rmd Strategic

CAGE 05869
View NSNs

Raytheon Company Dba Raytheon

CAGE 82577
View NSNs
Identification Data

DEMIL

A

HMIC

P

PMIC

A

ESD/EMI

Item Characteristics
MRCRequirementReply
AAQLBODY STYLESINGLE POLE TYPE
ADAQBODY LENGTH2.485 INCHES MINIMUM AND 2.515 INCHES MAXIMUM
ADATBODY WIDTH0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.925 INCHES MINIMUM AND 1.955 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.047 INCHES MINIMUM AND 2.077 INCHES MAXIMUM
AEGJSWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJECBOSS HEIGHT0.125 INCHES MINIMUM AND 0.155 INCHES MAXIMUM
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE2.595 INCHES MINIMUM AND 2.625 INCHES MAXIMUM
AKPXPOLE QUANTITY1
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE(S)
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE2.0 AMPERES AC SINGLE LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS115.0 AC SINGLE LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS2000.0 AC SINGLE LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC SINGLE LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATION
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 SINGLE LOCATION
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPRZAUXILIARY SWITCH FUNCTION AND QUANTITY1 ALARM
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATION
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQSMSWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE ONE
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.150 MINIMUM AT 200 PCT AND 1.500 MAXIMUM AT 200 PCT SINGLE LOCATION
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT
CRTKSWITCH TERMINAL TYPETAB, SOLDER LUG
CSSXSWITCH CURRENT RATING AND TYPE IN AMPS5.0 AC AND 1.0 DC
CSWPSWITCH VOLTAGE RATING AND TYPE IN VOLTS120.0 AC AND 50.0 DC
CTJSUNPACKAGED UNIT WEIGHT0.188 POUNDS NOMINAL
FREQFREQUENCY IN HERTZ60.0 SINGLE LOCATION
MATTMATERIALPLASTIC CASE
THSDTHREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TTQYTERMINAL TYPE AND QUANTITY2 THREADED STUD

Need full procurement data, packaging, and standardization info?

View Complete NSN Data on NSN Lookup

Quick Reference

NSN5925-00-646-3111
NIIN006463111
FSC5925
DEMILA
PARTS2
MFRS2

About NSN 5925-00-646-3111

NSN 5925-00-646-3111 is a National Stock Number assigned to Circuit Breaker. This NSN part number belongs to Federal Supply Class 5925 (CIRCUIT BREAKERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 2 part numbers associated with this NSN from 2 manufacturers.

To find the part number for NSN 5925-00-646-3111, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.