NSN

5925-00-069-1306

Circuit Breaker

FSC 5925CIRCUIT BREAKERSFSG 59ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS

Unit Price

$50.00

per EA

2 parts / 2 mfrs

Part Numbers for NSN 5925-00-069-13062 records
Part NumberCAGEManufacturerRNCCRNVC
70-197-2MG674193Eaton Corp Heinemann Products Commercial Controls Div39
13214E3711-397403Cecom Lr Center72
Manufacturers (2)

Eaton Corp Heinemann Products Commercial Controls Div

CAGE 74193
View NSNs

Cecom Lr Center

CAGE 97403
View NSNs
Price History
Effective DateUnit PriceUISLC
01-OCT-2025$50.00EA0
01-OCT-2025$50.00EA0
Identification Data

DEMIL

A

HMIC

P

PMIC

U

ESD/EMI

Item Characteristics
MRCRequirementReply
AAQLBODY STYLESINGLE POLE TYPE
ADAQBODY LENGTH2.540 INCHES MAXIMUM
ADATBODY WIDTH0.750 INCHES NOMINAL
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.970 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.060 INCHES NOMINAL
AEGJSWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
AJECBOSS HEIGHT0.140 INCHES NOMINAL
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE2.770 INCHES MAXIMUM
AKPXPOLE QUANTITY1
AXHRMOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE(S)
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE12.5 AMPERES AC SINGLE LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS230.0 AC SINGLE LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 AC SINGLE LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC SINGLE LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATION
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 SINGLE LOCATION
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPRZAUXILIARY SWITCH FUNCTION AND QUANTITY1 ALARM
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATION
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQSMSWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE ONE
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT4.000 MINIMUM AT 200 PCT AND 12.000 MAXIMUM AT 200 PCT SINGLE LOCATION
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDMOISTURE RESISTANT AND FUNGUS RESISTANT
CRTKSWITCH TERMINAL TYPETAB, SOLDER LUG
CSSXSWITCH CURRENT RATING AND TYPE IN AMPS2.5 AC
CSWPSWITCH VOLTAGE RATING AND TYPE IN VOLTS250.0 AC
FREQFREQUENCY IN HERTZ60.0 SINGLE LOCATION
MATTMATERIALPLASTIC CASE
THSDTHREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TTQYTERMINAL TYPE AND QUANTITY2 THREADED STUD

Need full procurement data, packaging, and standardization info?

View Complete NSN Data on NSN Lookup

Quick Reference

NSN5925-00-069-1306
NIIN000691306
FSC5925
PRICE$50.00
DEMILA
PARTS2
MFRS2

About NSN 5925-00-069-1306

NSN 5925-00-069-1306 is a National Stock Number assigned to Circuit Breaker. This NSN part number belongs to Federal Supply Class 5925 (CIRCUIT BREAKERS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 2 part numbers associated with this NSN from 2 manufacturers.

The current government unit price for NSN 5925-00-069-1306 is $50.00. Price history shows 2 recorded price changes.

To find the part number for NSN 5925-00-069-1306, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.