5915-00-824-7975
Filter,Radio Frequency Interfere
6 parts / 4 mfrs
| Part Number | CAGE | Manufacturer | RNCC | RNVC |
|---|---|---|---|---|
| FA4098 | 13619 | Ems Development Corporation Dba Ems Development Corp | 5 | 2 |
| RF00200 | 13619 | Ems Development Corporation Dba Ems Development Corp | 5 | 2 |
| RF-200 | 13619 | Ems Development Corporation Dba Ems Development Corp | 5 | 9 |
| 9150639 | 18876 | Us Army Aviation and Missile Command | 3 | 2 |
| 9150636 | 50369 | Active and Passive Components Inc | 5 | 2 |
| FA4098 | 81831 | Filtron Co Inc Div of Rfi Corp | 5 | 9 |
Ems Development Corporation Dba Ems Development Corp
CAGE 13619Us Army Aviation and Missile Command
CAGE 18876Active and Passive Components Inc
CAGE 50369Filtron Co Inc Div of Rfi Corp
CAGE 81831DEMIL
A
HMIC
Y
PMIC
U
ESD/EMI
| MRC | Requirement | Reply |
|---|---|---|
| ABKW | OVERALL HEIGHT | 3.628 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 4.750 INCHES NOMINAL |
| ADAT | BODY WIDTH | 1.938 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 2.719 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.125 INCHES NOMINAL |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.125 INCHES NOMINAL |
| AFGA | OPERATING TEMP RANGE | -40.0 TO 85.0 CELSIUS |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.1 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.1 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.3 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.3 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.3 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| AKNA | INCLOSURE TYPE | ENCASED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 WIRE HOOK OUTPUT THIRD FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 14 WIRE HOOK INPUT FIRST FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 300.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 300.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 300.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS DC 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS DC 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| CQJX | NOMINAL THREAD SIZE | 0.164 INCHES |
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
About NSN 5915-00-824-7975
NSN 5915-00-824-7975 is a National Stock Number assigned to Filter,Radio Frequency Interfere. This NSN part number belongs to Federal Supply Class 5915 (FILTERS AND NETWORKS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 6 part numbers associated with this NSN from 4 manufacturers.
To find the part number for NSN 5915-00-824-7975, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.