5915-00-166-8166
Filter,Radio Frequency Interfere
Unit Price
$546.12
per EA
5 parts / 5 mfrs
| Part Number | CAGE | Manufacturer | RNCC | RNVC |
|---|---|---|---|---|
| RF9287 | 13619 | Ems Development Corporation Dba Ems Development Corp | 5 | 9 |
| LMF1288 | 29098 | Lindgren Rf Enclosures Inc Lectromagnetics Div | 5 | 9 |
| 63-010 | 32155 | Polara Engineering, Inc. | 3 | 2 |
| 8833300002-1 | 57057 | Navcom Defense Electronics, Inc. | 7 | 9 |
| 573A94 | 94033 | Cardwell Condenser Corp Lapointe-Admiral Div | 5 | 2 |
Ems Development Corporation Dba Ems Development Corp
CAGE 13619Lindgren Rf Enclosures Inc Lectromagnetics Div
CAGE 29098Polara Engineering, Inc.
CAGE 32155Navcom Defense Electronics, Inc.
CAGE 57057Cardwell Condenser Corp Lapointe-Admiral Div
CAGE 94033| Effective Date | Unit Price | UI | SLC |
|---|---|---|---|
| 01-OCT-2025 | $546.12 | EA | 0 |
| 01-OCT-2025 | $546.12 | EA | 0 |
DEMIL
D
HMIC
P
PMIC
U
ESD/EMI
| MRC | Requirement | Reply |
|---|---|---|
| ABKW | OVERALL HEIGHT | 2.250 INCHES MAXIMUM |
| ADAQ | BODY LENGTH | 6.220 INCHES MINIMUM AND 6.280 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 1.440 INCHES MINIMUM AND 1.500 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 1.770 INCHES MINIMUM AND 1.830 INCHES MAXIMUM |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 5.820 INCHES MINIMUM AND 5.840 INCHES MAXIMUM |
| AECR | VIBRATION RESISTANCE RANGE IN HERTZ | +10.0 TO 2000.0 |
| AFGA | OPERATING TEMP RANGE | -55.0 TO 95.0 CELSIUS |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.5 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.5 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.5 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 400.0 MILLIVOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 750.0 MILLIVOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 750.0 MILLIVOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 750.0 MILLIVOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| AKNA | INCLOSURE TYPE | ENCASED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 7 TURRET GROUND THIRD FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 5 TAB, SOLDER LUG INPUT FIRST FUNCTION |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 TAB, SOLDER LUG OUTPUT SECOND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 26.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
| CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 322.0 VOLTS AT SEA LEVEL |
| STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
About NSN 5915-00-166-8166
NSN 5915-00-166-8166 is a National Stock Number assigned to Filter,Radio Frequency Interfere. This NSN part number belongs to Federal Supply Class 5915 (FILTERS AND NETWORKS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 5 part numbers associated with this NSN from 5 manufacturers.
The current government unit price for NSN 5915-00-166-8166 is $546.12. Price history shows 2 recorded price changes.
To find the part number for NSN 5915-00-166-8166, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.