5910-00-101-4014
Capacitor,Fixed,Mica Dielectric
9 parts / 7 mfrs
| Part Number | CAGE | Manufacturer | RNCC | RNVC |
|---|---|---|---|---|
| 935-4217-000 | 13499 | Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems | 5 | 1 |
| 1014014 | 18876 | Us Army Aviation and Missile Command | 5 | 1 |
| 0161-4 | 56232 | Lockheed Martin Corporation Div Rms - Mitchel Field | 5 | 1 |
| 241-20074-1 | 64294 | Danfoss Fluid Power Inc Racine Opn | 5 | 9 |
| 48983E5 | 80064 | Naval Ship Systems Command | 5 | 1 |
| CM30E102J | 81349 | Military Specifications Promulgated By Military Departments/Agencies Under Authority of Defense Standardization Manual 4120 3-M | 2 | 2 |
| MILC5 | 81349 | Military Specifications Promulgated By Military Departments/Agencies Under Authority of Defense Standardization Manual 4120 3-M | 4 | 1 |
| 935-4217-00 | 95104 | Alcatel-Lucent Holdings Inc. | 5 | 1 |
| 935-4217-000 | 95104 | Alcatel-Lucent Holdings Inc. | 5 | 1 |
Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems
CAGE 13499Us Army Aviation and Missile Command
CAGE 18876Lockheed Martin Corporation Div Rms - Mitchel Field
CAGE 56232Danfoss Fluid Power Inc Racine Opn
CAGE 64294Naval Ship Systems Command
CAGE 80064Military Specifications Promulgated By Military Departments/Agencies Under Authority of Defense Standardization Manual 4120 3-M
CAGE 81349Alcatel-Lucent Holdings Inc.
CAGE 95104DEMIL
A
HMIC
P
PMIC
U
ESD/EMI
| MRC | Requirement | Reply |
|---|---|---|
| AAQL | BODY STYLE | W/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABJT | TERMINAL LENGTH | 1.120 INCHES MINIMUM |
| ADAQ | BODY LENGTH | 0.800 INCHES NOMINAL |
| ADAT | BODY WIDTH | 0.250 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 0.800 INCHES NOMINAL |
| AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
| CQBQ | CAPACITANCE VALUE PER SECTION | 1000.000 PICOFARADS SINGLE SECTION |
| CQJJ | NONDERATED OPERATING TEMP | -55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM |
| CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 500.0 DC SINGLE SECTION |
| CRDN | TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS | -20.0 TO 100.0 SINGLE SECTION |
| CRTP | TOLERANCE RANGE PER SECTION | -5.00 TO 5.00 PERCENT SINGLE SECTION |
| CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
| MATT | MATERIAL | PLASTIC CASE |
| TEST | TEST DATA DOCUMENT | 81349-MIL-C-5 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems
CAGE 13499
Us Army Aviation and Missile Command
CAGE 18876
Lockheed Martin Corporation Div Rms - Mitchel Field
CAGE 56232
Danfoss Fluid Power Inc Racine Opn
CAGE 64294
Naval Ship Systems Command
CAGE 80064
Military Specifications Promulgated By Military Departments/Agencies Under Authority of Defense Standardization Manual 4120 3-M
CAGE 81349
Alcatel-Lucent Holdings Inc.
CAGE 95104
About NSN 5910-00-101-4014
NSN 5910-00-101-4014 is a National Stock Number assigned to Capacitor,Fixed,Mica Dielectric. This NSN part number belongs to Federal Supply Class 5910 (CAPACITORS) under Federal Supply Group 59 (ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS). There are 9 part numbers associated with this NSN from 7 manufacturers.
To find the part number for NSN 5910-00-101-4014, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.