5895-00-342-9460
Gate,Electronic
4 parts / 3 mfrs
| Part Number | CAGE | Manufacturer | RNCC | RNVC |
|---|---|---|---|---|
| 652BM101-7 | 26687 | Teledyne Brown Engineering, Inc. Dba Teledyne Advanced Electronic Solutions Div Teledyne Advanced Electronic Solutions | 5 | 2 |
| TD-108/UPA-35 | 80058 | Joint Electronics Type Designation System | 5 | 2 |
| A15642 | 80249 | Bae Systems Information and Electronic Systems Integration Inc. | 3 | 2 |
| A15642-1 | 80249 | Bae Systems Information and Electronic Systems Integration Inc. | 5 | 2 |
Teledyne Brown Engineering, Inc. Dba Teledyne Advanced Electronic Solutions Div Teledyne Advanced Electronic Solutions
CAGE 26687Joint Electronics Type Designation System
CAGE 80058Bae Systems Information and Electronic Systems Integration Inc.
CAGE 80249DEMIL
D
HMIC
N
PMIC
U
ESD/EMI
| MRC | Requirement | Reply |
|---|---|---|
| ABHP | OVERALL LENGTH | 11.812 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 5.500 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 10.125 INCHES NOMINAL |
| AFSU | AVERAGE LIFE MEASUREMENT | NOT RATED |
| AGAV | END ITEM IDENTIFICATION | AN/UPA-35 |
| AGTA | BASIC SHAPE STYLE | RECTANGULAR OR SQUARE |
| AKNA | INCLOSURE TYPE | ENCASED |
| AMQY | INSTALLATION DESIGN | RACK |
| BHSX | CIRCUIT CONSTRUCTION TYPE | SOLID STATE |
| BHTP | PULSE DURATION PER CHANNEL | 1500.000 MICROSECONDS NOMINAL 2ND OUTPUT CHANNEL |
| BHTP | PULSE DURATION PER CHANNEL | 1.000 MICROSECONDS NOMINAL 4TH OUTPUT CHANNEL |
| BHTP | PULSE DURATION PER CHANNEL | 1675.000 MICROSECONDS NOMINAL 5TH OUTPUT CHANNEL |
| BHTP | PULSE DURATION PER CHANNEL | 1270.000 MICROSECONDS NOMINAL 7TH OUTPUT CHANNEL |
| BHTP | PULSE DURATION PER CHANNEL | 1325.000 MICROSECONDS NOMINAL 1ST OUTPUT CHANNEL |
| BHTP | PULSE DURATION PER CHANNEL | 1325.000 MICROSECONDS NOMINAL 6TH OUTPUT CHANNEL |
| BHTP | PULSE DURATION PER CHANNEL | 1500.000 MICROSECONDS NOMINAL 3RD OUTPUT CHANNEL |
| BHTS | POLARITY PER CHANNEL | POSITIVE 3RD OUTPUT CHANNEL |
| BHTS | POLARITY PER CHANNEL | NEGATIVE 6TH OUTPUT CHANNEL |
| BHTS | POLARITY PER CHANNEL | NEGATIVE 5TH OUTPUT CHANNEL |
| BHTS | POLARITY PER CHANNEL | NEGATIVE 1ST OUTPUT CHANNEL |
| BHTS | POLARITY PER CHANNEL | POSITIVE 4TH OUTPUT CHANNEL |
| BHTS | POLARITY PER CHANNEL | POSITIVE 7TH OUTPUT CHANNEL |
| BHTS | POLARITY PER CHANNEL | NEGATIVE 2ND OUTPUT CHANNEL |
| BHTT | PULSE REPETITION RATE PER CHANNEL | 200.000 PULSES PER SECOND MINIMUM OPERATING CHANNEL AND 600.000 PULSES PER SECOND MAXIMUM OPERATING CHANNEL |
| BHTW | PULSE PEAK AMPLITUDE PER CHANNEL | 200.000 VOLTS 5TH OUTPUT CHANNEL |
| BHTW | PULSE PEAK AMPLITUDE PER CHANNEL | 292.000 VOLTS 7TH OUTPUT CHANNEL |
| BHTW | PULSE PEAK AMPLITUDE PER CHANNEL | 106.000 VOLTS 2ND OUTPUT CHANNEL |
| BHTW | PULSE PEAK AMPLITUDE PER CHANNEL | 184.000 VOLTS 1ST OUTPUT CHANNEL |
| BHTW | PULSE PEAK AMPLITUDE PER CHANNEL | 200.000 VOLTS 6TH OUTPUT CHANNEL |
| BHTW | PULSE PEAK AMPLITUDE PER CHANNEL | 56.000 VOLTS 4TH OUTPUT CHANNEL |
| BHTW | PULSE PEAK AMPLITUDE PER CHANNEL | 133.000 VOLTS 3RD OUTPUT CHANNEL |
| BHTZ | SIGNAL DATA TYPE PER CHANNEL | 7TH OUTPUT CHANNEL PULSE |
| BHTZ | SIGNAL DATA TYPE PER CHANNEL | 1ST OUTPUT CHANNEL PULSE |
| BHTZ | SIGNAL DATA TYPE PER CHANNEL | 5TH OUTPUT CHANNEL PULSE |
| BHTZ | SIGNAL DATA TYPE PER CHANNEL | 6TH OUTPUT CHANNEL PULSE |
| BHTZ | SIGNAL DATA TYPE PER CHANNEL | 3RD OUTPUT CHANNEL PULSE |
| BHTZ | SIGNAL DATA TYPE PER CHANNEL | 4TH OUTPUT CHANNEL PULSE |
| BHTZ | SIGNAL DATA TYPE PER CHANNEL | 2ND OUTPUT CHANNEL PULSE |
| BJBJ | OUTPUT WAVE SHAPE | RECTANGULAR AND PULSE, GATE |
| BJBQ | OPERATING AC FREQUENCY IN HERTZ | 60.0 NOMINAL 1ST VOLTAGE |
| BJBQ | OPERATING AC FREQUENCY IN HERTZ | 60.0 NOMINAL 2ND VOLTAGE |
| BJBQ | OPERATING AC FREQUENCY IN HERTZ | 60.0 NOMINAL 3RD VOLTAGE |
| BKFB | EXTERNAL DC OPERATING VOLTAGE IN VOLTS | 220.0 NOMINAL 1ST VOLTAGE |
| BKFB | EXTERNAL DC OPERATING VOLTAGE IN VOLTS | -180.0 NOMINAL 2ND VOLTAGE |
| BKFB | EXTERNAL DC OPERATING VOLTAGE IN VOLTS | -350.0 NOMINAL 3RD VOLTAGE |
| BKFC | EXTERNAL AC OPERATING VOLTAGE IN VOLTS | 6.3 NOMINAL 3RD VOLTAGE |
| BKFC | EXTERNAL AC OPERATING VOLTAGE IN VOLTS | 6.3 NOMINAL 2ND VOLTAGE |
| BKFC | EXTERNAL AC OPERATING VOLTAGE IN VOLTS | 6.3 NOMINAL 1ST VOLTAGE |
| FAAZ | PHASE | SINGLE |
| FAAZ | PHASE | SINGLE |
| FAAZ | PHASE | SINGLE |
| FTLD | FUNCTIONAL DESCRIPTION | PROVIDES BASIC TIMING GATES FOR INDICATOR,AZIMUTH AND RANGE IP-207/UPA-35 |
Need full procurement data, packaging, and standardization info?
View Complete NSN Data on NSN LookupQuick Reference
About NSN 5895-00-342-9460
NSN 5895-00-342-9460 is a National Stock Number assigned to Gate,Electronic. This NSN part number belongs to Federal Supply Class 5895 (MISCELLANEOUS COMMUNICATION EQUIPMENT) under Federal Supply Group 58 (COMMUNICATION, DETECTION, AND COHERENT RADIATION EQUIPMENT). There are 4 part numbers associated with this NSN from 3 manufacturers.
To find the part number for NSN 5895-00-342-9460, refer to the part number cross-reference table above. Each part number is linked to its manufacturer through a CAGE (Commercial and Government Entity) code.